ProGuard — post, rails and finish
Post, outer size50 × 50 mm (1.97 × 1.97 in)
Post wall2.0 mm (0.079 in)
MaterialGalvanised carbon steel
GradeQ355D (GB/T 1591)
Finish5-stage powder coat, matte black; HDG option after welding
Post weight3.01 kg/m
Guard heights36 in and 42 in
Guard rail top rail50 × 50 × 1.5 mm, 6 ft max span
Cable top rail2 × 1 in × 2.5 mm, 4 ft max span
Base plate115 × 115 × 10 mm, 4 × Ø11 mm holes at 3.25 in centres, 5/8 in edge distance
Safety factor at the code load, on the tolerance-minimum wall
HeightSafety factorLoad case
36 in3.16 ×200 lb concentrated, any direction (IRC R301.5)
42 in1.34 × commercial case 50 lb/ft uniform = 300 lb per post at 6 ft spacing (IBC 1607.9.1)
What this is and is not a claim of

We hold no ICC-ES evaluation report and no Intertek CCRR. Every figure here is our own engineering against published code requirements and published material minimums. It is not a third-party rating. The full working, with a live calculator, is on our Engineering & Code Compliance page.

What it is for

  • Raised decks, balconies and stair guards at 36 in and 42 in
  • Commercial work — it is sized against the IBC uniform load, not just the residential one
  • Anywhere more than one storey up

What it is not for

  • Salt air within about a mile of the coast — that is CoastLine
  • Nothing else. This is the general-purpose structural line

Why it is specified this way

The load case that actually sizes this post is not the one people quote

Everyone quotes the 200 lb concentrated load. But IBC 1607.9.1 also applies a 50 lb per foot uniform load along the top rail, and at a 6 ft post spacing that is 300 lb per post — half again more than the concentrated load. That is the case ProGuard is sized against, and it is the real line between a residential guard and a commercial one.

Why a 2.0 mm wall and not 3.0

On Q355 at the tolerance-minimum wall, 2.0 mm carries 1.34× against that governing commercial case and 2.01× against the concentrated one. 3.0 mm would give 1.91× and weigh 4.43 kg/m instead of 3.01 — 47% more steel for margin the code does not ask for. We would rather pass honestly than over-build expensively.

Every number here is on the wall the mill may legally ship

Chinese cold-formed hollow section carries a −10% wall tolerance, so a 2.0 mm nominal may arrive at 1.80. Every safety factor on this page is computed at nominal × 0.90 — not at the wall the drawing says.

Everything else in this set